Audio Database

SH-9020M
Commentary

A peak / average meter unit developed for the purpose of reading as accurately as possible even at the recording level.

3 mode switching of peak / peak hold / average is possible, and 1 meter can be used for 3 different types according to the purpose.

The meter sensitivity can be switched between 0 dBm and 20 dBm.
An indication range from -50dB to + 10 dB is possible for each, and an indication range of 80 dB is secured by using a sensitivity change-over switch.

The input of the Route 3 can be switched with the push button.
You can read the power amp output, recording output, and preamplifier output by simply switching the buttons.

Model Rating
Type Peak / average meter unit
Input Sensitivity / Impedance
(Sens. 0 dBm, + 20 dBm)
Inputs 1 and 2 : 20 dBm (7.75 v) / 47k Ω, 0 dBm (0.775 v) / 47k Ω
input3 : 100W (8 Ω, 4 Ω) / 10k Ω, 1W (8 Ω, 4 Ω) / 10k Ω
Sensitivity 0 dB, + 20 dB
Frequency characteristic 10 Hz to 20 kHz ± 1.5 dB (+ 10 to -40dB)
10 Hz to 10 kHz ± 3 dB (less than -40dB)
Attack time
(Rise Time)
330msec(average)
100 μ sec (peak, peak hold)
Recovery time
(Return Time)
Average : 250 msec (0 → -20dB)
Peak : 750 msec (0 → -20dB)
Peak hold : 25 min or more (0 → -3db)
Meter range + 10 to -50dB
Indication accuracy input1, 2 : 0 ± 1.5 dB (input + 20 dBm, Sens. 0 dB) (input 0 dBm, Sens. + 20 dB)
input3 : 0 ± 2 dB (input 100W, Sens. 0 dB) (input 1W, Sens + 20 dB)
Pwer 100 VAC, 50Hz/60Hz
Power consumption 10W
External dimensions Width 450x Height 92x Depth 378 mm
Weight 5.3kg