Audio Database

Image of GT-210
Commentary

FM/AM tuner kit with PLL that can be completed in 4 hours.

The front end, IF block and MPX section of GT-210 have been adjusted and wired on one printed circuit board.
In addition, all blocks such as power supply blocks and switch blocks are assembled on the Kencraft production line after adjustment.

A PLL circuit is used in the MPX section to realize a circuit resistant to secular changes and changes in temperature and humidity.

The front end uses MOS type FET and frequency linear type 3-row variable capacitor, and the IF stage uses high-integration IC and 2-stage ceramic filter.
This makes it possible to receive clear sound from a station located at a long distance or in a strong electric field area.

It is equipped with an MPX noise filter to cut out noise components that cause concern when receiving FM stereo broadcast transmission.

Equipped with FM stereo indicator using LED.

The AM tuner uses a high-integration IC.
It provides stable AGC characteristics regardless of whether the input is strong or weak, enabling AM reception with less distorted sound.
The bar antenna is designed to be built into the case.

Equipped with a meter for both tuning and signal.
It acts as a center tuning meter to indicate the best tuning point when receiving FM, and as a signal meter to indicate the strongest point of input when receiving AM.

Model Rating
Type FM/AM Tuner Kit
FM Tuner Section
Receiving frequency 76 MHz to 90 MHz
Antenna impedance 300 Ω equilibrium
75 Ω unbalance
Sensitivity (IHF standard) 2.0 μ V
Chinese arrowhead's slope 5 μ V : 50 dB
10 μ V : 56 dB
50 μ V : 58 dB
Distortion Factor (400 Hz, 100% modulation) mono:0.5%
stereo:0.8%
S/N ratio (100% modulation, 1 mV input) mono:60dB
Image ratio 40dB
Selectivity (IHF) 41dB
IF interference ratio 80dB
Harmonic spurious response 80dB
AM suppression ratio 50dB
Capture ratio 3.0dB
Stereo separation 30 dB (50 Hz to 10 kHz)
Carrier leakage 45dB
Frequency characteristic 50 Hz ~ 13 kHz + 0 -3dB
<AM Tuner Section>
Receiving frequency 520 kHz to 1605 kHz
Sensitivity (IHF standard) 20 μ V
Distortion factor 1.0%
Signal-to-noise ratio 40 dB (30% modulation, 1 mV input)
<Others>
Output Level / Impedance FM (400 Hz, 100% modulation) : 1.0V/2k Ω
AM (400 Hz, 30% modulation) : 150mV/2k Ω
Pwer 100 VAC, 50Hz/60Hz
Rated power consumption (Electrical Appliance and Material Control Law) 10W
External dimensions Width 372x Height 125x Depth 252 mm
Weight 3.5kg