TAD TN-1
¥ 140,000 (around 1991)
¥ 160,000 (around 1993)
Commentary
A dividing network of 4 Ω specification to drive two TL 1601 a in parallel.
It is adopted in Exclusive model2402twin.
The design philosophy of low loss and low leakage is thoroughly carried out by introducing OFC (oxygen-free copper) into all wiring cords and choke coil winding, press-joint type connection using OFC sleeve, enlargement and gold plating of terminal, development and adoption of high-quality condenser, etc.
By making the LF circuit a balanced circuit, we have succeeded in eliminating the leakage caused by the ground line.
In addition, it is custom-designed to bring out the performance of each combined unit, such as completely separating the HF and LF circuits and eliminating noise turbidity near the crossover frequency.
Model Rating
Type | Two way dividing network |
Crossover frequency | 650Hz |
Max Input | 600W |
Impedance | 4 Ω |
Level control | Internal : fixed -6dB External : Continuously Variable Type |
Constant loss | TN-1 L.F.0.6dB |
Damping property | TN-1 L.F.:-36dB/oct TN-1 H.F.:-12dB/oct |
External dimensions | TN-1L. F. : 250 mm wide x 300 mm high x 142 mm deep TN-1H. F. : 330 mm wide x 59 mm high x 150 mm deep |
Weight | TN-1 L.F.:3.3kg TN-1 H.F.:1.8kg |
Accessories | Mounting screws (Tapping screw M4x25) x10 Plain Washer x10 Y-terminal x14 Sealed Packing x1 One level controller |