¥ 9,000 (released in 1983)
Commentary
AC volt meter adapter kit of measuring instrument series.
High sensitivity AC volt meter (millibar) function can be obtained by using M-8M or DC meter of commercial tester.
It can be used as a highly sensitive voltmeter covering a wide range from 1 mV to 300 V maximum, and can be used for waveform observation with a oscillograph.
You can also measure the specifications of an audio amplifier by combining it with various measuring instruments.
In general, a tester rectifies AC voltage into DC voltage and swings a DC meter. The M-2V uses only the DC meter part of the tester with a built-in rectifier that is much higher in performance than the tester.
The circuit configuration is the same as that of a full-scale AC voltmeter, and high sensitivity is obtained.
The attenuator uses a precision resistor to improve reliability.
Model Rating
Type | AC Volt Meter Adapter Kit |
Input terminal | One pin jack |
Output terminal | Chip Jack for Tester x2 Output pin jack x1 |
Input resistance | 1M Ω |
Measuring range | 1 mv ~ 300 v, 12 range |
Frequency characteristic | 20 Hz ~ 100 kHz ± 0.5 dB (for 1 kHz) |
Stability | + / - 0.3 dB for a variation of 9 V + / - 10% (When 9 v battery is used) |
Output voltage | Approximately 1 Vrms at full scale |
Pwer | Built-in Battery (006Px2) ± 15 V, 20 mA external power supply available |
External dimensions | Width 227x Height 65x Depth 155 mm |
Weight | 850g (excluding battery) |