Step-up transformer for MC using toroidal core.

By developing and adopting a ring-shaped toroidal core, nonlinear distortion and noise components caused by hysteresis curve and Barkhausen effect are eliminated.

Model Rating
Type Booster transformer
Primary impedance 10 Ω, 30 Ω, PASS (Switching)
Secondary impedance 12k Ω
Load impedance 47k Ω ~ 50k Ω
Boost ratio 10 Ω : 31 dB (36 times)
30 Ω : 26 dB (21 times)
Frequency band 20 Hz to 30 kHz
Distortion factor Measurement error occurs until output 2 vrms and judgment is not made.
External dimensions 64 mm wide x 64 mm high x 105 mm deep