Electro Acustic/ELAC 444
444-E : 28,800 (around 1970)
444-12 : 25,900 (around 1970)
Commentary
MM type cartridge corresponding to the top model.
444-E uses an elliptical needle, and 444-12 uses a 0.5 mil needle.
The elliptical needle can suppress the distortion caused by the pinch effect.
Model Rating
Type | MM Type Cartridge | |
Model Name | 444-E | 444-12 |
Frequency characteristic | 10 Hz to 24 kHz | |
Proper needle pressure | 0.75 ~ 1.5g | |
Output voltage | 10mV/10cm/s | |
Channel balance | 1.5 dB or Less (1 kHz) | |
Channel separation | 26 dB or More (1 kHz) | |
Traceability | 075g/100Hz(3.8cm/s) | |
Compliance | 33x10cm-6/dyne | |
Stylus Diameter | 0.2x0.8mil | 0.5mil |
Vertical tracking angle | 15 ° | |
Coil inductance | 320mH | |
Load impedance | 47k Ω | |
Cartridge Finish Color | Chrome | |
Grip Finish Color | Black | |
Exchange needle | D444-E(¥18,100) | D444-12(¥15,700) |