LUXKIT M-5GL
¥ 12,000 (released in 1983)
Commentary
Low distortion generator kit of measuring instrument series.
The M-5GL was developed mainly for measuring the distortion rate of audio amplifiers. For this purpose, the oscillation frequency is set at 3 points of 100 Hz, 1 kHz and 10 kHz, which are often used for measuring the distortion rate, and an ultra-low distortion rate of the level required for measuring audio amplifiers is achieved.
A quadrature circuit using a state variable filter is used for the oscillation circuit to realize an oscillation waveform with an ultra-low distortion factor.
Uses a high-performance, low-noise OP amplifier.
It uses an attenuator with 600 Ω constant output impedance that can be changed in conjunction with 10 dB steps.
Equipped with oscillation frequency fine adjustment function.
Model Rating
Type | Low distortion generator kit |
Oscillation frequency | 100 Hz, 1 kHz, 10 kHz |
Fine adjustment range | + / - 3% or more |
Output voltage | 3 Vrms (output open) |
Distortion Factor (at maximum output) | 100 Hz : 0.0015% or less 1 kHz : 0.0015% or less 10 kHz : 0.0025% or less |
Attenuator | 10 dB step, -40dB and continuously variable |
Output impedance | 600 Ω |
Pwer | Internal : 9 v Battery 006Px2 External : ± 15 ~ 17V/30mA |
External dimensions | Width 227x Height 67x Depth 151 mm |
Weight | 850g (excluding battery) |