Audio Database

DA-309
Commentary

Universal tone arm developed as a more user-friendly dynamic damping type arm.

A dynamic damping mechanism has been adopted to reduce the influence of natural and external vibration of each part of the arm.
In this system, the tone arm pipe and body part are divided, and the arm moves freely in the vertical and horizontal directions, and it is connected with a フレキシプル coupler that suppresses the motion of the tone arm pipe in the axial direction and rotational direction. The fulcrum side of the pipe is braked by an appropriate viscoelastic material.
With this structure, the vibration coming from the arm base is damped and the natural vibration of each part of the arm is greatly reduced. When the arm base is vibrated by a vibrator and measured, an improvement effect of up to 15 dB compared with a tone arm without a damping mechanism is realized.

Equipped with a contact-free inside four scan seller.
In this system, a tapered magnetic plate is wound around a rotating drum, and a magnet is used. When the magnet is brought close to the rotating drum, a rotational force is generated that attracts the magnetic plate from the narrow side to the wider side within the winding range angle of the magnetic plate. This rotational torque is used to cancel the inside force.
The DA 309 adjusts the rotational torque for each needle pressure by changing the distance between the rotary drum and the magnet. Since this method is non-contact structure, the performance of the tone arm is not impaired. Moreover, since it can follow the change of inside force due to the position of the needle tip of the cartridge on the record, the appropriate outside force can always be obtained.
In addition, the cancellation mechanism can be turned off with one touch, making it convenient for 0 balance adjustment.

The head shell adopts a new structure shell.
Resonance is damped by combining a magnesium alloy that is lightweight and highly rigid with a special viscoelastic body that has a large internal loss.

Most cartridges can be mounted by using the attached sub-weight.

The lever of the arm lifter is provided on the front side in consideration of operability.

Uses a low-capacity output cord.

Model Rating
Type Static balanced tone arm
Total Length 340 mm (maximum)
Effective length 244mm
Offset Angle 20.5 ゜
Overhang 14mm
Height adjustment range 42 ~ 70 mm (From Cabinet Board Surface to Pipe Center)
Tracking error 2.5 ゜
Needle pressure adjustment range 5g ~ 15g
15g ~ 25g (Use Attached Sub Weight)
Head shell Combination of magnesium alloy diecasting and viscoelastic body
Head shell dead weight About 9g
Inside for scan seller Magnetic Control System (With Release Mechanism)
Arm lifter Oil dump type
Mountable Board Thickness 5 ~ 25 mm
Output code Low-capacity cord (with 5P connector)